Replacement For Sullair Air Compressor After Cooler 88290020-396
Replacement for Sullair Air Compressor After Cooler 88290020-396

1. The function of a Sullair cooler: Sullair coolers are classified as either water-cooled or air-cooled depending on the type of heat exchange medium they use. Mobile machines typically have integrated coolers with both water storage and cooling capabilities, also known as water tanks, due to the difficulty of external cooling water sources.
Heat exchanger is another name for the Sullair cooler. Its primary purpose is to disperse heat produced during Sullair air compressor operation through the medium exchange, lowering the air compressor's working temperature and ensuring the long-term performance of the critical components. the goal of trouble-free performance. In addition, part of the moisture will condense and be released from the trap once the moistened compressed air is cooled, which will enhance the compressed air's quality.
2. The Sullair cooler's mechanism of operation
The pressure differential in the system drives the flow of Sullair air compressor oil, which moves from the separator tank to the primary compressor. The temperature control valve closes when the oil temperature drops below 77°C, allowing the oil to bypass the Sullair cooler and run directly through the oil filter to the main engine's operating points. The temperature of the oil gradually increases as the heat produced by the compression process is absorbed. The temperature control valve begins to open when the oil temperature reaches 77°C (88°C for the 24KT model), allowing some of the oil to go through the oil filter and into the Sullair cooler before entering the main engine.
3. Upkeep of a Sullair cooler
The Sullair cooler's ability to exchange heat will be compromised when oil, grease, dust, and other debris build-up on its surface, which will raise the exhaust temperature. Use a vacuum cleaner, cleaning solution, or low-pressure compressed air to clean the Sullair cooler's exterior once every two weeks. The aftercooler's condensed water needs to be evacuated often when the surrounding air is humid or cold. The condensed water in the aftercooler must be evacuated every day when the temperature is below 0°C.
Send a WhatsApp message to +8615618652003 or send an email to [email protected] for more information when looking for a Sullair replacement after cooler for PN 88290020-396 from a reputable China Supplier. Please compare your Sullair After Cooler part numbers with a few on-site cooler photographs for a quick quote. We'll check it out and get back to you in two hours.